EN ISO 11612: Protection against heat and flame (global standard for EN531)

The EN ISO 11612 standard specifies the performance requirements for protective clothing EN 11612 Heat and flame protection which must protect the user's body (with the exception of the hands) against heat and/or flames. The performance requirements set out in EN ISO 11612 apply to protective clothing that can be worn for a variety of purposes, for example where clothing with limited flame spread is required and where the user may be exposed to radiant, convective or contact heat or splashes of molten metal. The standard does not apply to firefighters (EN 469) and welders (EN ISO 11611). The requirements include: performance after pre-treatment of the fabric, accessories, mechanical properties, dimensional stability etc.


 

Test results

The standard contains a number of tests regarding the cloth. The results of these tests are represented by the letters A, B, C, D, E and F. If a letter is not mentioned or the class is '0', the lowest value has not been achieved or the test has not been carried out; the clothing then offers no protection against this property.

A: A1 or A2 (surface or edge ignition)

Were tested based on the index 3 test of the EN ISO 15025 standard

B: Convection heat ISO 915

Performance level Transfer Convective Heat Index (HTI24)
Min Max
B1 4.0 s < 10 s
B2 10.0 s < 20 s
B3 20.0 s

C: Radiant heat test ISO 6942, heat flux 20 kW/m²

The clothing must achieve at least C1

Performance level Transfer radiant heat index (HTI24)
Min Max
C1 7.0 sec < 20 s
C2 20.0 s < 50 s
C3 50.0 sec < 95 s
C4 90.0 s

D: Splashes of molten aluminum ISO 9185

The clothing must achieve at least D1

Performance level Splashes of molten aluminum
Min Max
D1 100g < 200g
D2 200g <350g
D3 350g

E: Splashes of molten iron ISO 9185

The clothing must achieve at least E1

Performance level Splashes of molten iron
Min Max
E1 60g < 120g
E2 120g < 200g
E3 200g

F: Contact heat ISO 12127 - 250 degrees

The clothing must achieve at least F1

Performance level Contact heat
Min Max
F1 5.0 s 10.0 s
F2 10, s 15.0 s